[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100623472":3},{"organization":4,"armGroups":7,"interventions":14,"overallOfficials":23,"centralContacts":24,"locations":30,"responsibleParty":44,"collaborators":46,"id":50,"slug":51,"hasResults":52,"nctId":53,"briefTitle":54,"officialTitle":55,"acronym":23,"eligibilityCriteria":56,"healthyVolunteers":57,"sex":58,"minAge":59,"maxAge":23,"enrollmentInfo":60,"targetDuration":23,"studyType":63,"phases":64,"briefSummary":66,"conditions":67,"keywords":70,"overallStatus":72,"whyStopped":23,"lastUpdateSubmitDate":73,"lastUpdatePostDateStruct":74,"startDateStruct":77,"completionDateStruct":79,"leadSponsor":81,"locationsCount":82},{"fullName":5,"class":6},"Murata Vios, Inc.","INDUSTRY",[8],{"label":9,"type":10,"description":11,"interventionNames":12},"Concurrent Monitoring","EXPERIMENTAL","Subjects wear Moni-Patch on the neck and tympanic sensor in the ear for concurrent continuous temperature monitoring for 15 minutes after stabilization.",[13],"Device: Moni-Patch Temperature Monitoring Patch System",[15],{"type":16,"name":17,"description":18,"armGroupLabels":19,"otherNames":20},"DEVICE","Moni-Patch Temperature Monitoring Patch System","Wireless neck-applied Sensor paired with a Receiver via Bluetooth; heat flux and thermistor-based estimation of core temperature; sampling every 30 seconds.",[9],[21,22],"MP-P20U (Sensor)","MP-D20U (Receiver)",null,[25],{"name":26,"role":27,"phone":28,"phoneExt":23,"email":29},"Ash Shibata","CONTACT","+1-612-497-7397","a.shibata@murata.com",[31],{"facility":32,"status":23,"city":33,"state":34,"zip":35,"country":36,"countryCode":37,"cosmosGeoPoint":38,"geoPoint":43,"contacts":23},"Murata Vios","Woodbury","Minnesota","55125","United States","US",{"type":39,"coordinates":40},"Point",[41,42],-92.95938,44.92386,{"lat":42,"lon":41},{"type":45,"investigatorFullName":23,"investigatorTitle":23,"investigatorAffiliation":23,"oldNameTitle":23,"oldOrganization":23},"SPONSOR",[47],{"name":48,"class":49},"Sonoma State University","OTHER","100623472","clinical-accuracy-validation-of-the-moni-patch-temperature-monitoring-patch-system-100623472",false,"NCT07397078","Clinical Accuracy Validation of the Moni-Patch Temperature Monitoring Patch System","Moni-Patch Temperature Monitoring Patch System Clinical Accuracy Validation","Inclusion Criteria:\n\n* Age ≥ 7 years\n* Agree to Sensor placement on the neck and ear\n\nExclusion Criteria:\n\n* Ear conditions contraindicating tympanic probe; skin issues at placement sites\n* Antipyretic use within 120 minutes; inability to position neck Sensor over carotid\n* Inability to seal tympanic sensor; tympanic membrane not visually confirmed",true,"ALL","7 Years",{"count":61,"type":62},105,"ESTIMATED","INTERVENTIONAL",[65],"NA","Moni-Patch Temperature Monitoring Patch System, a non-invasive, continuous temperature monitoring device designed to estimate core body temperature by applying a Sensor to the neck.\n\nThis clinical accuracy validation study aims to verify the accuracy and repeatability of the Moni-Patch compared with an FDA-cleared continuous tympanic temperature monitoring device used as the clinical reference.\n\nMain objectives of this study are; To verify that the Moni-Patch and the reference device(tympanic) demonstrate acceptable agreement, as defined by Bland-Altman Analyses (bias within ±0.4°C and limits of agreement between -1.0°C and 1.0°C).\n\nTo verify the consistency and repeatability of temperature measurements obtained from the Moni-Patch during continuous monitoring.",[68,69],"Body Temperature","Febrile",[71],"Core body temperature","NOT_YET_RECRUITING","2026-02-05",{"date":75,"type":76},"2026-02-09","ACTUAL",{"date":78,"type":62},"2026-01-21",{"date":80,"type":62},"2026-03-31",{"name":5,"class":6},1]