[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100598664":3},{"organization":4,"armGroups":7,"interventions":19,"overallOfficials":11,"centralContacts":29,"locations":35,"responsibleParty":51,"collaborators":11,"id":53,"slug":54,"hasResults":55,"nctId":56,"briefTitle":57,"officialTitle":57,"acronym":58,"eligibilityCriteria":59,"healthyVolunteers":55,"sex":60,"minAge":61,"maxAge":11,"enrollmentInfo":62,"targetDuration":11,"studyType":65,"phases":66,"briefSummary":68,"conditions":69,"keywords":11,"overallStatus":37,"whyStopped":11,"lastUpdateSubmitDate":71,"lastUpdatePostDateStruct":72,"startDateStruct":75,"completionDateStruct":77,"leadSponsor":79,"locationsCount":80},{"fullName":5,"class":6},"Clinique Victor Pauchet","OTHER",[8,14],{"label":9,"type":10,"description":11,"interventionNames":12},"TECHNIC BY CATAPULSE","EXPERIMENTAL",null,[13],"Procedure: EYE 1 SURGERY BY CATAPULSE TECHNIC",{"label":15,"type":16,"description":11,"interventionNames":17},"TECHNIC BY PHACOEMULSIFICATION","ACTIVE_COMPARATOR",[18],"Procedure: EYE 2 SURGERY BY CATAPULSE TECHNIC",[20,25],{"type":21,"name":22,"description":23,"armGroupLabels":24,"otherNames":11},"PROCEDURE","EYE 1 SURGERY BY CATAPULSE TECHNIC","In arm 2: 1st eye operated by high-frequency pulsed vacuum technology \u002F 2nd eye operated by phacoemulsification",[9],{"type":21,"name":26,"description":27,"armGroupLabels":28,"otherNames":11},"EYE 2 SURGERY BY CATAPULSE TECHNIC","In arm 1: 1st eye operated by phacoemulsification \u002F 2nd eye operated by high-frequency pulsed vacuum technology",[15],[30],{"name":31,"role":32,"phone":33,"phoneExt":11,"email":34},"Aurélie DUSSAUSSOY, Clinical research associated","CONTACT","+33 3 22 33 74 78","aurelie.dussaussoy@pauchet.com",[36],{"facility":5,"status":37,"city":38,"state":11,"zip":39,"country":40,"countryCode":41,"cosmosGeoPoint":42,"geoPoint":47,"contacts":48},"RECRUITING","Amiens","80090","France","FR",{"type":43,"coordinates":44},"Point",[45,46],2.3,49.9,{"lat":46,"lon":45},[49],{"name":50,"role":32,"phone":33,"phoneExt":11,"email":34},"Aurélie DUSSAUSSOY",{"type":52,"investigatorFullName":11,"investigatorTitle":11,"investigatorAffiliation":11,"oldNameTitle":11,"oldOrganization":11},"SPONSOR","100598664","comparative-study-of-high-frequency-pulsed-vacuum-technology-versus-phacoemulsification-for-cataract-surgery-100598664",false,"NCT07074431","\"Comparative Study of High-frequency Pulsed Vacuum Technology Versus Phacoemulsification for Cataract Surgery","PULSEM","Inclusion Criteria:\n\n* Adult patient\n* Patient with bilateral cataracts\n* Grade 1 to 3 cataracts\n* Indication for bilateral cataract surgery\n* Patient informed of the study and having given their written and signed informed consent\n* Patient affiliated with a social security scheme or beneficiary of such a scheme\n\nExclusion Criteria:\n\n* Refusal of consent\n* Cataract grade \\> 3\n* Unilateral and\u002For combined cataract surgery\n* Uveitic cataract\n* Glaucoma\n* Patient with ocular comorbidity\n* Patient with cognitive impairment preventing them from responding to satisfaction questionnaires\n* Patient unable to read, write, or understand French\n* Pregnant or breastfeeding patient as defined in Article L1121-5 of the French Public Health Code\n* Vulnerable patient as defined in Article L1121-6 of the French Public Health Code\n* Adult patient under guardianship, curatorship, or legal protection\n* Patient unable to give personal consent","ALL","18 Years",{"count":63,"type":64},60,"ESTIMATED","INTERVENTIONAL",[67],"NA","Cataracts are cloudings of the lens, primarily due to aging. Surgery is the primary treatment for cataracts. The most commonly used surgical technique is phacoemulsification, which involves fragmenting the lens using a high-frequency ultrasound probe and removing the fragments. Phacoemulsification is more common due to its advantages.\n\nRecently, a new approach has emerged, using high-frequency pulsed vacuum technology for cataract ablation. This less invasive approach is expected to allow for faster patient recovery and reduce surgical risks. High-frequency pulsed vacuum utilizes the pulse-pulse principle by interrupting the vacuum every tenth of a second. This interruption creates an impact moment between the cataract material and the cannula tip, dissecting the cataract without damaging the surrounding delicate tissue. High-frequency pulsed vacuum maintains anterior chamber stability while creating sufficient dissection to aspirate the cataract material. This energy also cools the tip, allows for better vacuum control, and significantly reduces turbulence within the eye. More importantly, high-frequency pulsed vacuum disrupts endothelial cells less and causes less edema than mechanical ultrasound.\n\nThis technique therefore appears ideal for treating patients with at-risk corneas (low endothelial cell count, risk of decompensation and corneal transplantation).\n\nThe objective of the study is to demonstrate the benefits of this approach using high-frequency pulsed vacuum technology through a randomized, comparative, crossover study.",[70],"Cataract Bilateral","2026-03-26",{"date":73,"type":74},"2026-03-31","ACTUAL",{"date":76,"type":74},"2025-12-12",{"date":78,"type":64},"2027-01",{"name":5,"class":6},1]