[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100583759":3},{"organization":4,"armGroups":7,"interventions":18,"overallOfficials":27,"centralContacts":28,"locations":38,"responsibleParty":55,"collaborators":27,"id":57,"slug":58,"hasResults":59,"nctId":60,"briefTitle":61,"officialTitle":62,"acronym":63,"eligibilityCriteria":64,"healthyVolunteers":59,"sex":65,"minAge":66,"maxAge":27,"enrollmentInfo":67,"targetDuration":27,"studyType":70,"phases":71,"briefSummary":73,"conditions":74,"keywords":78,"overallStatus":41,"whyStopped":27,"lastUpdateSubmitDate":85,"lastUpdatePostDateStruct":86,"startDateStruct":89,"completionDateStruct":91,"leadSponsor":93,"locationsCount":94},{"fullName":5,"class":6},"Elsan","OTHER",[8,14],{"label":9,"type":10,"description":11,"interventionNames":12},"UC TKA","ACTIVE_COMPARATOR","The Score II® is a primary cruciate-sacrificing TKA, with a single-radius femoral component that articulates in an ultra-congruent (UC) mobile-bearing tibial insert. The mobile-bearing tibial insert has high anterior and posterior borders to avoid anterior subluxation of the femoral condyles during knee flexion and a concave articular surface with a radius of curvature that matches that of the femoral component in the sagittal plane to ensure high congruence. The Score II® UC TKA comprises eight sizes and offers the choice of using a cemented or uncemented version. In this study, only the cemented version will be used.",[13],"Procedure: total knee arthroplasty",{"label":15,"type":10,"description":16,"interventionNames":17},"PS TKA","The Anatomic® is a primary PS TKA with a fixed-bearing polyethylene insert. The femoral component has a cam design that engages on a tibial post to provide anterior-posterior stability during flexion. The Anatomic® PS TKA comprises nine cemented sizes. In this study, only the cemented version will be used. The Anatomic® PS TKA comprises nine cemented sizes.",[13],[19],{"type":20,"name":21,"description":22,"armGroupLabels":23,"otherNames":24},"PROCEDURE","total knee arthroplasty","Replacement of knee articulating surface for patients with end-stage osteoarthritis.",[15,9],[25,26],"knee surgery","knee replacement",null,[29,34],{"name":30,"role":31,"phone":32,"phoneExt":27,"email":33},"Stéphane Van DRIESSCHE, MD","CONTACT","+33(0)637675746","svandri@gmail.com",{"name":35,"role":31,"phone":36,"phoneExt":27,"email":37},"Aurélia Cassany","+33(0)638229411","cassany@elsan.care",[39],{"facility":40,"status":41,"city":42,"state":27,"zip":43,"country":44,"countryCode":45,"cosmosGeoPoint":46,"geoPoint":51,"contacts":52},"St Marguerite clinic","RECRUITING","Auxerre","89000","France","FR",{"type":47,"coordinates":48},"Point",[49,50],3.57033,47.7996,{"lat":50,"lon":49},[53],{"name":54,"role":31,"phone":27,"phoneExt":27,"email":27},"Stephane Van Driessche, MD",{"type":56,"investigatorFullName":27,"investigatorTitle":27,"investigatorAffiliation":27,"oldNameTitle":27,"oldOrganization":27},"SPONSOR","100583759","comparing-articular-noise-and-its-perception-between-two-different-types-of-total-knee-arthroplasty-100583759",false,"NCT06880497","Comparing Articular Noise and Its Perception Between Two Different Types of Total Knee Arthroplasty","Monocentric, Randomized Study, Comparing Articular Noise and Its Perception Between Two Different Types of Total Knee Arthroplasty","NATKA","Inclusion Criteria:\n\n* Adult patients receiving a primary TKA\n* Signed informed consent\n* Patients affiliated to a social security scheme\n* Patients willing and able to comply with study protocol requirements based on the investigator's judgment.\n\nExclusion Criteria:\n\n* History of knee surgery on the concerned\u002Fstudied knee (except arthroscopic surgery)\n* Patients presenting coronal deformities \\> 20°, varus laxity \\> 10° and\u002For valgus laxity \\> 15°\n* Patients receiving revision TKA\n* Pregnancy or breast-feeding\n* Patients with protected status under articles L1121-6, LL121-8 and L1122-2 of the French Public Health Code\n* Unable to comply with study procedures, based on the investigator's judgment.","ALL","18 Years",{"count":68,"type":69},170,"ESTIMATED","INTERVENTIONAL",[72],"NA","Some patients complain of articular noise (such as clicking, snapping, cracking or popping) after a total knee replacement. Controversy remains about whether there is a correlation between articular noise and worse outcomes following a knee replacement. A study by Nam et al. on 1540 patients revealed an association between noise and residual symptoms 30 days after they received a total knee replacement. Conversely, a study by Kuriyama et al. on 60 patients revealed no correlation between noise and patient satisfaction after 1 year of receiving a total knee replacement. The incidence of noise following a knee replacement has rarely been studied as a primary outcome. Like pain, it could be considered an important patient-reported outcome to assess patient satisfaction. The study aims to compare the prevalence of patient-perceived noise of an ultra-congruent total knee prosthesis (Score 2, Amplitude) versus a posterior-stabilized total knee prosthesis (Anatomic, Amplitude).",[75,76,77],"Knee Osteoarthristis","Knee Replacement Arthroplasty","Knee Replacement, Total",[79,80,81,82,83,84],"Noise","Articular noise","Total Knee Arthroplasty","TKA","Total Knee Replacement","TKR","2026-03-02",{"date":87,"type":88},"2026-03-04","ACTUAL",{"date":90,"type":88},"2025-12-24",{"date":92,"type":69},"2028-12",{"name":5,"class":6},1]