[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100392131":3},{"organization":4,"armGroups":7,"interventions":14,"overallOfficials":22,"centralContacts":27,"locations":35,"responsibleParty":59,"collaborators":62,"id":68,"slug":69,"hasResults":70,"nctId":71,"briefTitle":72,"officialTitle":73,"acronym":31,"eligibilityCriteria":74,"healthyVolunteers":70,"sex":75,"minAge":76,"maxAge":77,"enrollmentInfo":78,"targetDuration":31,"studyType":81,"phases":82,"briefSummary":84,"conditions":85,"keywords":87,"overallStatus":37,"whyStopped":31,"lastUpdateSubmitDate":90,"lastUpdatePostDateStruct":91,"startDateStruct":94,"completionDateStruct":96,"leadSponsor":98,"locationsCount":99},{"fullName":5,"class":6},"Milton S. Hershey Medical Center","OTHER",[8],{"label":9,"type":10,"description":11,"interventionNames":12},"Continuous Glucose Monitoring","EXPERIMENTAL","All participants will have the continuous glucose monitoring device placed.",[13],"Device: Continuous Glucose Monitoring Device",[15],{"type":16,"name":17,"description":18,"armGroupLabels":19,"otherNames":20},"DEVICE","Continuous Glucose Monitoring Device","The Dexcom G7 Glucose Monitoring System (San Diego, CA) reports continuous interstitial blood glucose concentrations every 5 minutes, does not require calibration, and involves only 1 needle stick to place the sensor. The manufacturer recommends that a single sensor may be used for up to 10 days. The Dexcom G7 system is the only FDA approved CGM system for children (age \\>2 years).",[9],[21],"Dexcom G7",[23],{"name":24,"affiliation":25,"role":26},"Jeffrey R. Kaiser, MD, MA","Penn State Health Milton S Hershey Medical Center","PRINCIPAL_INVESTIGATOR",[28,33],{"name":24,"role":29,"phone":30,"phoneExt":31,"email":32},"CONTACT","717-531-8413",null,"jkaiser2@pennstatehealth.psu.edu",{"name":34,"role":29,"phone":31,"phoneExt":31,"email":31},"Kerry Deitrick, LPN",[36],{"facility":25,"status":37,"city":38,"state":39,"zip":40,"country":41,"countryCode":42,"cosmosGeoPoint":43,"geoPoint":48,"contacts":49},"RECRUITING","Hershey","Pennsylvania","17033","United States","US",{"type":44,"coordinates":45},"Point",[46,47],-76.65025,40.28592,{"lat":47,"lon":46},[50,51,56],{"name":24,"role":29,"phone":30,"phoneExt":31,"email":32},{"name":52,"role":29,"phone":53,"phoneExt":54,"email":55},"Kerry Deitick, LPN","717-531-5656","322261","kdeitrick1@pennstatehealth.psu.edu",{"name":57,"role":58,"phone":31,"phoneExt":31,"email":31},"Neha Patel, DO","SUB_INVESTIGATOR",{"type":26,"investigatorFullName":60,"investigatorTitle":61,"investigatorAffiliation":5,"oldNameTitle":31,"oldOrganization":31},"Natalie Allen","Assistant Professor, Pediatrics",[63,66],{"name":64,"class":65},"DexCom, Inc.","INDUSTRY",{"name":67,"class":6},"Children's Miracle Network","100392131","continuous-glucose-monitoring-in-at-risk-newborns-100392131",false,"NCT04386005","Continuous Glucose Monitoring in At-Risk Newborns","Continuous Glucose Monitoring in At-Risk Newborns: A Feasibility Study","Inclusion Criteria:\n\n* At-risk newborns (\\\u003C48 hours old, all sexes) admitted to the Newborn Nursery or the NICU who meet any of the below criteria:\n\n  1. Infant of a diabetic mother (IDM, pre-existing or gestational diabetes)\n  2. Large for gestational age (LGA, \\>90th percentile \\[sex-specific\\])\n  3. Small for gestational age (SGA, \\\u003C10th percentile \\[sex-specific\\])\n  4. Late preterm (LPT, 34 0\u002F7 to 36 6\u002F7 weeks' gestation)\n* Any newborn undergoing routine blood glucose screening in the newborn nursery per the Neonatal Hypoglycemia protocol (includes newborns of mothers taking oral hypoglycemic agents, beta-blocker medications, or systemic steroids within 7 days before delivery; and newborns with clinical manifestations of hypoglycemia)\n\nExclusion Criteria:\n\n* Birth weight \\\u003C2kg\n* hypoxic-ischemic encephalopathy\n* a contraindication to oral feeding\n* abnormal skin that will preclude placement of the CGM (e.g., skin on the thigh that is not intact)\n* chromosomal abnormalities or severe congenital anomalies identified ante- or postnatally\n* infants who are not expected to survive or who are in extremis\n* additional risk of immunocompromise, including:\n\n  1. Skin infections, such as staphylococcus or streptococcus skin infections and herpes (skin, eye, and mouth disease) infection\n  2. Skin diseases that add additional risk, such as epidermolysis bullosa, ichthyosis, peeling skin syndrome, and hemangiomas\n  3. Systemic sepsis, viral syndromes\n  4. Immune diseases such as severe combined immunodeficiency, cancer, T-cell or B-cell deficiencies, inborn errors of metabolism, chromosomal abnormalities, glycogen storage diseases, genetic diseases\n  5. Abdominal wall defects","ALL","1 Minute","2 Weeks",{"count":79,"type":80},100,"ESTIMATED","INTERVENTIONAL",[83],"NA","Hypoglycemia (low blood glucose) is a very common problem in newborns, and has been associated with poor neurodevelopment, cognition, and school performance. At-risk newborns (infants of diabetic mothers \\[IDM\\], large \\[LGA\\] and small \\[SGA\\] for gestational age infants, and late preterm \\[LPT\\] infants) undergo a hypoglycemia screening protocol that involves numerous intermittent needle sticks to test glucose levels on bedside glucometers; however, continuous glucose monitoring (CGM, currently not approved for clinical use in babies), via a small sensor placed in the thigh (only 1 needle stick), would likely decrease pain while providing continuous glucose levels. This study will evaluate the feasibility, safety, and precision of CGM in at-risk newborns, and determine if this method would decrease the amount of painful procedures and episodes of hypoglycemia missed by intermittent sampling.\n\nAs part of regular medical care, participants will undergo intermittent blood glucose screening with heel sticks as per the current hospital standard of care protocol. Regular medical care involves checking the participant's blood glucose via heel stick every few hours using a bedside glucometer, with another heel stick to confirm low values in the laboratory. If the participant has low values, he\u002Fshe may be treated with oral glucose gel, feedings of breast milk or formula, or intravenous (IV) fluids in the Neonatal Intensive Care Unit (NICU). This research study involves placing a CGM device in addition to undergoing the current blood glucose screening protocol and treatment.\n\nAs soon as possible after birth, a continuous glucose monitoring device (Dexcom G7) will be placed on the participant's thigh by a research team member, and will blindly continuously record glucose levels that will be analyzed after discharge. Everyone who agrees to participate in this study will have placement of this experimental device.\n\nThe investigational device will stay in place for the same amount of time that a participant is undergoing blood glucose monitoring as per the current standard of care protocol, for a maximum of 7 days. A participant may need to have his\u002Fher blood glucose checked after 7 days for regular medical care (and not for research), because his\u002Fher glucose concentrations are still low. Being in the research study will not affect a participant's medical care, and will not affect how long he\u002Fshe needs blood glucose monitoring or treatment.\n\nA research team member will place and remove the CGM. Nurses will evaluate the site of the device for signs of irritation, infection, bleeding, and any other issues at least 3 times per day. After discharge from the hospital, data will be collected from the participant's medical record and participant's mother's medical record, including the participant's sex and birth weight, blood glucose values, details of feedings, treatments given for low glucose concentrations, and NICU admission data. Data that will be collected from the participant's mother's medical record includes age and race, prenatal data, medical history, and medication use. The participant's parents will be asked to fill out a short survey about their experience with this device when it is removed.",[86],"Neonatal Hypoglycemia",[88,89],"blood glucose","continuous glucose monitor","2025-08-12",{"date":92,"type":93},"2025-08-15","ACTUAL",{"date":95,"type":93},"2021-08-09",{"date":97,"type":80},"2026-06",{"name":5,"class":6},1]