[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100634724":3},{"organization":4,"armGroups":7,"interventions":14,"overallOfficials":20,"centralContacts":21,"locations":27,"responsibleParty":43,"collaborators":20,"id":45,"slug":46,"hasResults":47,"nctId":48,"briefTitle":49,"officialTitle":50,"acronym":51,"eligibilityCriteria":52,"healthyVolunteers":47,"sex":53,"minAge":54,"maxAge":55,"enrollmentInfo":56,"targetDuration":20,"studyType":59,"phases":60,"briefSummary":62,"conditions":63,"keywords":65,"overallStatus":68,"whyStopped":20,"lastUpdateSubmitDate":69,"lastUpdatePostDateStruct":70,"startDateStruct":73,"completionDateStruct":75,"leadSponsor":77,"locationsCount":78},{"fullName":5,"class":6},"Neurosoft Bioelectronics SA","INDUSTRY",[8],{"label":9,"type":10,"description":11,"interventionNames":12},"MINDZ Subdural Electrode Grid for Intraoperative Neurophysiological Monitoring","EXPERIMENTAL","This is a single arm study with no comparator. The MINDZ subdural electrode will be used in addition to the standard of care work flow.",[13],"Device: MINDZ Subdural Electrode Grid",[15],{"type":16,"name":17,"description":18,"armGroupLabels":19,"otherNames":20},"DEVICE","MINDZ Subdural Electrode Grid","The study intervention is limited to the insertion of the investigational device through the burr hole (up to 15 minutes), followed by an additional 5-minute recording using the device, resulting in a total extension of approximately 20 minutes to the standard surgical procedure. The data recorded using the investigational device will not be used for clinical decision-making.\n\nFollowing completion of the recording, the device will be removed through the burr hole, and the surgery will proceed according to the standard clinical protocol.",[9],null,[22],{"name":23,"role":24,"phone":25,"phoneExt":20,"email":26},"Clinical and Regulatory Affairs Manager","CONTACT","+41762190000","clinical@neurosoft-bio.com",[28],{"facility":29,"status":20,"city":30,"state":20,"zip":20,"country":31,"countryCode":32,"cosmosGeoPoint":33,"geoPoint":38,"contacts":39},"University Hospital Zurich","Zurich","Switzerland","CH",{"type":34,"coordinates":35},"Point",[36,37],8.55,47.36667,{"lat":37,"lon":36},[40],{"name":41,"role":24,"phone":42,"phoneExt":20,"email":26},"Senior Physician, Department of Neurosurgery","004100000000",{"type":44,"investigatorFullName":20,"investigatorTitle":20,"investigatorAffiliation":20,"oldNameTitle":20,"oldOrganization":20},"SPONSOR","100634724","mindz---minimally-invasive-approach-pilot-study-100634724",false,"NCT07543406","MINDZ-- Minimally Invasive Approach Pilot Study","MINDZ-- Minimally Invasive Approach Pilot Study Single Center, First-in-Human Evaluation of MINDZ Electrode- Demonstrating the Feasibility of Safe, Burr-hole Deployment and Functional Efficacy","MINDZ-MAP","Inclusion Criteria:\n\n* Age ≥18 and ≤75 years at the time of enrolment.\n* Patients diagnosed with a brain tumour or epilepsy who require neurosurgical intervention. This includes patients undergoing craniotomy for brain surgery without the need for intracranial electrode monitoring, as well as patients undergoing neurosurgery with intraoperative neurophysiological monitoring using subdural electrodes. Specifically, this includes patients for whom subdural strip electrodes are indicated and planned to be implanted through standard-size burr holes (e.g., for phase-reversal evaluation)\n* Participants capable and willing to provide informed consent for participation in the trial.\n\nExclusion Criteria:\n\n* History of significant psychiatric impairments which, in the opinion of the investigator, will interfere with the proper administration or completion of the protocol.\n* Any medical condition that contradicts neurosurgical intervention (i.e., acute or ongoing untreated infections, anticoagulant medication that cannot be discontinued, factor XIII deficiency or any other hematological disease).\n* Participation in another clinical study.\n* Known intolerances to the materials used in the soft device (medical grade silicone or platinum).\n* Vulnerable subject groups (e.g., pregnancy or lactation, prisoners, etc.).\n* Any other significant disease or disorder which, in the opinion of the investigator, may either put the participants at risk because of participation in the trial, or may influence the result of the trial, or the participant's ability to participate in the trial.","ALL","18 Years","75 Years",{"count":57,"type":58},5,"ESTIMATED","INTERVENTIONAL",[61],"NA","This clinical investigation is a pilot, first-in-human (FIH) study designed to demonstrate proof of concept, safety, and functional performance of the MINDZ subdural electrode grid when used in relevant neurosurgical settings. The study will provide initial clinical evidence to support future conformity assessment and CE marking under the European Medical Device Regulation (MDR).\n\nThe investigational device, MINDZ, developed by Neurosoft Bioelectronics, is a novel, soft and highly conformable subdural electrode grid designed for minimally invasive implantation through a burr hole. Its flexible structure is intended to improve conformity to the cortical surface, reduce dead space between the electrode and brain tissue, and potentially lower the risk of complications associated with craniotomy, while maintaining adequate cortical coverage for effective monitoring and mapping.",[64],"Intraoperative Neurophysiological Monitoring",[66,67],"cortical electrode","IONM","NOT_YET_RECRUITING","2026-04-15",{"date":71,"type":72},"2026-04-21","ACTUAL",{"date":74,"type":58},"2026-05-01",{"date":76,"type":58},"2027-06-01",{"name":5,"class":6},1]