[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100581154":3},{"organization":4,"armGroups":7,"interventions":20,"overallOfficials":26,"centralContacts":31,"locations":37,"responsibleParty":53,"collaborators":26,"id":57,"slug":58,"hasResults":59,"nctId":60,"briefTitle":61,"officialTitle":62,"acronym":26,"eligibilityCriteria":63,"healthyVolunteers":59,"sex":64,"minAge":26,"maxAge":26,"enrollmentInfo":65,"targetDuration":26,"studyType":68,"phases":69,"briefSummary":71,"conditions":72,"keywords":74,"overallStatus":40,"whyStopped":26,"lastUpdateSubmitDate":79,"lastUpdatePostDateStruct":80,"startDateStruct":83,"completionDateStruct":85,"leadSponsor":87,"locationsCount":88},{"fullName":5,"class":6},"Cairo University","OTHER",[8,15],{"label":9,"type":10,"description":11,"interventionNames":12},"Intra-Orally Scanned Dentures","EXPERIMENTAL","Arm Description:\n\nParticipants in this arm will receive maxillary dentures fabricated using intra-oral scanning technology. Digital impressions of the oral cavity will be captured directly using the 3Shape TRIOS intraoral scanner, eliminating the need for conventional impression materials. These digital impressions will be used to design and 3D-print the dentures, which will then be fitted and evaluated for comfort, fit, and aesthetics. Participants will wear these dentures for a specified period and provide feedback through structured satisfaction surveys.",[13,14],"Device: Intra-Oral Scanning Method","Device: Extra orally scanned",{"label":16,"type":17,"description":18,"interventionNames":19},"Extra-Orally Scanned Dentures","ACTIVE_COMPARATOR","Arm Description:\n\nParticipants in this arm will receive maxillary dentures fabricated using extra-oral scanning technology. Conventional impressions of the oral cavity will first be taken using traditional impression materials. These impressions will then be scanned externally using the 3Shape scanner to create digital models. The digital models will be used to design and 3D-print the dentures, which will then be fitted and evaluated for comfort, fit, and aesthetics. Participants will wear these dentures for a specified period and provide feedback through structured satisfaction surveys.",[13,14],[21,27],{"type":22,"name":23,"description":24,"armGroupLabels":25,"otherNames":26},"DEVICE","Intra-Oral Scanning Method","Intervention Description:\n\nThe intra-oral scanning method involves capturing digital impressions of the oral cavity directly using the 3Shape scanner. This method eliminates the need for traditional impression materials, providing a more comfortable and precise imaging process. The digital impressions are then utilized to design and fabricate maxillary dentures using 3D printing technology. The intervention focuses on evaluating patient satisfaction with the dentures in terms of comfort, fit, and aesthetics.",[16,9],null,{"type":22,"name":28,"description":29,"armGroupLabels":30,"otherNames":26},"Extra orally scanned","The extra-oral scanning method involves creating conventional impressions of the oral cavity using traditional impression materials. These impressions are then scanned externally using the 3Shape scanner to produce digital models. The digital models are used to design and fabricate maxillary dentures through 3D printing technology. This intervention aims to assess patient satisfaction with the dentures based on comfort, fit, and aesthetics.",[16,9],[32],{"name":33,"role":34,"phone":35,"phoneExt":26,"email":36},"Lujayn A Mahmoud, BDS","CONTACT","01000642385","Lujaynamr@dentistry.cu.edu.eg",[38],{"facility":39,"status":40,"city":41,"state":26,"zip":42,"country":43,"countryCode":44,"cosmosGeoPoint":45,"geoPoint":50,"contacts":51},"Faculty of dentistry-Cairo university","RECRUITING","Cairo","22022","Egypt","EG",{"type":46,"coordinates":47},"Point",[48,49],31.24967,30.06263,{"lat":49,"lon":48},[52],{"name":33,"role":34,"phone":35,"phoneExt":26,"email":36},{"type":54,"investigatorFullName":55,"investigatorTitle":56,"investigatorAffiliation":5,"oldNameTitle":26,"oldOrganization":26},"PRINCIPAL_INVESTIGATOR","Lujayn Amr Mahmoud","Master Degree Student, Removable prosthodontics department, Faculty of Dentistry, CairoUniversity","100581154","patient-satisfaction-with-intra-oral-vs-extra-oral-scanned-3d-printed-dentures-an-in-vivo-study-100581154",false,"NCT06846619","\"Patient Satisfaction with Intra-Oral Vs. Extra-Oral Scanned 3D-Printed Dentures: an in Vivo Study\"","Patient Satisfaction of Intra-orally Scanned Versus Extra-orally Scanned Digitally Printed Maxillary Denture in Completely Edentulous Patients, in Vivo Study.","Inclusion Criteria:\n\n* Completely edentulous patients\n* Angle's Class I skeletal relationship\n* Normal facial symmetry\n* Cooperative patients\n\nExclusion Criteria:\n\n* -Temporomandibular disorders\n* Uncontrolled diabetes\n* Patient's with neuromuscular disorders\n* Severe psychiatric disorders\n* Angle's class II and III skeletal relationship.","ALL",{"count":66,"type":67},8,"ESTIMATED","INTERVENTIONAL",[70],"NA","The goal of this clinical trial is to evaluate patient satisfaction with intra-orally scanned versus extra-orally scanned digitally printed maxillary dentures in completely edentulous patients. The main questions it aims to answer are:\n\n1. Do intra-orally scanned dentures provide higher patient satisfaction compared to extra-orally scanned dentures?\n2. Are there significant differences in comfort, fit, aesthetics and phonetics between the two types of dentures?\n\nResearchers will compare the intra-orally scanned denture group to the extra-orally scanned denture group to determine if one method leads to superior patient-reported outcomes.\n\nParticipants will:\n\n* Receive both types of dentures (intra-orally scanned and extra-orally scanned), with a three-week wash-out period between each intervention.\n* Complete satisfaction surveys to assess comfort, fit, and aesthetics after using each type of denture.\n\nThe study aims to provide evidence on the optimal scanning method for digitally printed maxillary dentures in edentulous patients.",[73],"Complete Edentulism",[75,76,77,78],"Intraoral scanning","Extra oral scaning","Complete edentulism","Digital","2025-02-20",{"date":81,"type":82},"2025-02-26","ACTUAL",{"date":84,"type":82},"2023-12-03",{"date":86,"type":67},"2025-09-01",{"name":5,"class":6},1]