[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100608162":3},{"organization":4,"armGroups":7,"interventions":20,"overallOfficials":26,"centralContacts":31,"locations":41,"responsibleParty":59,"collaborators":26,"id":63,"slug":64,"hasResults":65,"nctId":66,"briefTitle":67,"officialTitle":68,"acronym":69,"eligibilityCriteria":70,"healthyVolunteers":65,"sex":71,"minAge":72,"maxAge":73,"enrollmentInfo":74,"targetDuration":26,"studyType":77,"phases":78,"briefSummary":80,"conditions":81,"keywords":83,"overallStatus":44,"whyStopped":26,"lastUpdateSubmitDate":87,"lastUpdatePostDateStruct":88,"startDateStruct":91,"completionDateStruct":93,"leadSponsor":95,"locationsCount":96},{"fullName":5,"class":6},"Beijing Tiantan Hospital","OTHER",[8,14],{"label":9,"type":10,"description":11,"interventionNames":12},"Experimental group","EXPERIMENTAL","Endovascular angioplasty with NxiDIME™ Intracranial Drug-Eluting self-expanding Stent System",[13],"Device: NxiDIME™ Intracranial Drug-Eluting Stent System",{"label":15,"type":16,"description":17,"interventionNames":18},"Controal group","ACTIVE_COMPARATOR","Endovascular angioplasty with NOVA Intracranial Drug-Eluting Balloon-expandable Stent",[19],"Device: NOVA DES Intracranial Drug-Eluting Stent",[21,27],{"type":22,"name":23,"description":24,"armGroupLabels":25,"otherNames":26},"DEVICE","NxiDIME™ Intracranial Drug-Eluting Stent System","The experimental group will receive the NxiDIME™ Intracranial Drug-Eluting self-expanding Stent System (RICOTON Technology Co., Ltd.)",[9],null,{"type":22,"name":28,"description":29,"armGroupLabels":30,"otherNames":26},"NOVA DES Intracranial Drug-Eluting Stent","The experimental group will receive the NOVA DES Intracranial Drug-Eluting balloon-expandable stent System",[15],[32,37],{"name":33,"role":34,"phone":35,"phoneExt":26,"email":36},"Feng Gao, Ph.D","CONTACT","13581936066","geofengletter@sina.com",{"name":38,"role":34,"phone":39,"phoneExt":26,"email":40},"Ming Yang","13331060083","wireyang20@163.com",[42],{"facility":43,"status":44,"city":45,"state":46,"zip":47,"country":48,"countryCode":49,"cosmosGeoPoint":50,"geoPoint":55,"contacts":56},"A prospective, multi-center, randomized controlled, non-inferiority clinical trial to evaluate the safety and efficacy of the NxiDIME™ Intracranial Drug-Eluting Stent System in the treatment of symptomatic intracranial atherosclerotic stenosis lesions","RECRUITING","Beijing","Beijing Municipality","100000","China","CN",{"type":51,"coordinates":52},"Point",[53,54],116.39723,39.9075,{"lat":54,"lon":53},[57],{"name":58,"role":34,"phone":39,"phoneExt":26,"email":40},"Ming Yang, Ph.D",{"type":60,"investigatorFullName":61,"investigatorTitle":62,"investigatorAffiliation":5,"oldNameTitle":26,"oldOrganization":26},"PRINCIPAL_INVESTIGATOR","Feng Gao","Professor","100608162","phase-3-drug--eluting-stent-for-symptomatic-intracranial-arterial-stenosis-100608162",false,"NCT07197970","Drug- Eluting Stent for Symptomatic Intracranial Arterial Stenosis","A Prospective, Multi-center, Randomized Controlled, Clinical Trial to Evaluate the Safety and Efficacy of NxiDIME™ Intracranial Drug-eluting Self-expanding Stent System","DESIAS","Inclusion Criteria:\n\n1. Age ≥ 18 years old and ≤ 80 years old, regardless of gender.\n2. Symptomatic intracranial arterial stenosis (TIA\u002Fischemic stroke within 180 days attributed to intracranial arteries including the intracranial internal carotid artery, middle cerebral artery, intracranial vertebral artery, or basilar artery, with stenosis severity ≥70% and ≤99% measured by DSA using WASID criteria), currently receiving at least one antiplatelet therapy;\n3. Poor collateral circulation or hypoperfusion in the target vessel territory (Poor collateral circulation: American Society of Interventional and Therapeutic Neuroradiology\u002FSociety of Interventional Radiology (ASITN\u002FSIR) score \\\u003C 3; Hypoperfusion: 1. The cerebral blood flow (CBF) in the target artery territory decreases by \\> 30% during CT or magnetic resonance perfusion imaging (MR perfusion); or 2. There are hemodynamic ischemic lesions on MRI or CT, such as watershed infarction);\n4. Target lesion vessel diameter 1.0-5.5 mm with lesion length ≤40 mm (If: 2.25 mm ≤ target vessel diameter ≤4.0 mm and lesion length ≤15 mm, enroll in randomized controlled study; 1.0 mm ≤ target vessel diameter \\\u003C2.25 mm or 4.0 mm \\\u003C target vessel diameter ≤5.5 mm or 15 mm \\\u003C lesion length ≤40 mm, enroll in single-arm cohort study);\n5. mRS score ≤ 2;\n6. Patient or legal guardian voluntarily participates and signs the written ICF, with willingness to comply with protocol-specified examinations and follow-up.\n\nExclusion Criteria:\n\n1. History of prior stent implantation or surgical treatment at the target lesion;\n2. Intracranial hemorrhage within 30 days preoperatively or presence of untreated chronic subdural hematoma ≥5 mm;\n3. Major surgical procedure within 30 days prior to the procedure;\n4. Acute ischemic stroke within 14 days prior to the procedure;\n5. Symptomatic carotid stenosis ≥50% outside the target lesion, or coexisting intracranial\u002Fextracranial vascular stenosis ≥70% requiring intervention;\n6. Severe calcification, significant stenosis, or tortuosity of the target vessel precluding device deployment as assessed by investigators;\n7. Intracranial tumor, arteriovenous malformation, or tandem aneurysms proximal\u002Fdistal to the target lesion;\n8. Non-atherosclerotic stenosis etiology (e.g., arterial dissection, moyamoya disease, vasculitis);\n9. Cardiac thromboembolic sources (e.g., atrial fibrillation, left ventricular thrombus, myocardial infarction within 6 weeks);\n10. Uncontrolled hypertension (persistent systolic blood pressure (SBP) ≥180 mmHg or diastolic blood pressure (DBP) ≥110 mmHg);\n11. Contraindications to antiplatelet\u002Fanticoagulant therapy, coagulopathy or bleeding diathesis precluding intervention per investigator judgment;\n12. Severe comorbidities: cardiac failure (New York Heart Association (NYHA) Class III-IV), respiratory\u002Frenal failure (serum creatinine \\>3.0 mg\u002FdL (264 μmol\u002FL)), Alanine Aminotransferase (ALT) or Aspartate Aminotransferase (AST) more than 3 times the upper limit of the normal value), active malignancy;\n13. Hypersensitivity to rapamycin, polylactic-co-glycolic acid, nitinol, platinum-tungsten, anesthetics, or contrast agents;\n14. Life expectancy \\\u003C1 year;\n15. Pregnancy, lactation, or planned pregnancy within 1 year;\n16. Concurrent participation in other clinical trials without completing primary endpoint follow-up;\n17. Cognitive impairment or psychiatric disorders compromising protocol compliance; other exclusionary conditions per investigator discretion.","ALL","18 Years","80 Years",{"count":75,"type":76},224,"ESTIMATED","INTERVENTIONAL",[79],"PHASE3","This investigation is a prospective, multicenter, randomized controlled, non-inferiority clinical trial, to evaluate the safety and efficacy of the investigational device against alternative models\u002Fspecifications of the control device. The study will be conducted across multiple Chinese centers, with planned enrollment of 224 patients with symptomatic intracranial atherosclerotic stenosis. Subjects meeting all inclusion criteria and without any exclusion criteria will enter the investigation after providing written informed consent via ethics committee-approved informed consent forms (ICFs). The randomized controlled study plans to enroll 224 patients, stratified by intracranial lesion location (anterior\u002Fposterior circulation), through a centralized randomization system. The experimental group will receive the NxiDIME™ Intracranial Drug-Eluting Stent System (RICOTON Technology Co., Ltd.), while the control group will receive the NOVADES® Intracranial Drug-Eluting Stent System.\n\nAll subjects underwent follow-up visits on the day of the procedure, within 7 days postoperatively or prior to discharge, and at 30 days, 6 months, and 12 months postoperatively.",[82],"Symptomatic Intracranial Atherosclerotic Stenosis",[84,85,86],"symptomatic intracranial atherosclerotic stenosis","Drug-Eluting Stent","strok","2025-09-25",{"date":89,"type":90},"2025-09-30","ACTUAL",{"date":92,"type":90},"2025-05-15",{"date":94,"type":76},"2027-05-15",{"name":5,"class":6},1]