[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100619381":3},{"organization":4,"armGroups":7,"interventions":14,"overallOfficials":20,"centralContacts":21,"locations":20,"responsibleParty":27,"collaborators":20,"id":29,"slug":30,"hasResults":31,"nctId":32,"briefTitle":33,"officialTitle":33,"acronym":34,"eligibilityCriteria":35,"healthyVolunteers":31,"sex":36,"minAge":37,"maxAge":20,"enrollmentInfo":38,"targetDuration":20,"studyType":41,"phases":42,"briefSummary":44,"conditions":45,"keywords":51,"overallStatus":54,"whyStopped":20,"lastUpdateSubmitDate":55,"lastUpdatePostDateStruct":56,"startDateStruct":59,"completionDateStruct":61,"leadSponsor":63,"locationsCount":20},{"fullName":5,"class":6},"Fundació Institut de Recerca de l'Hospital de la Santa Creu i Sant Pau","OTHER",[8],{"label":9,"type":10,"description":11,"interventionNames":12},"Ultrasound study","EXPERIMENTAL","Prior to SBT: A complete set of pulmonary, cardiac, and VExUS ultrasounds will be performed and stored for later analysis by blinded experts.\n\nAt the end of SBT: repeat pulmonary and cardiac ultrasounds",[13],"Diagnostic Test: point of care ultrasound",[15],{"type":16,"name":17,"description":18,"armGroupLabels":19,"otherNames":20},"DIAGNOSTIC_TEST","point of care ultrasound","Complete set of pulmonary, cardiac, and VExUS ultrasounds",[9],null,[22],{"name":23,"role":24,"phone":25,"phoneExt":20,"email":26},"Luis Zapata, MD PhD","CONTACT","+349329100","lzapata@santpau.cat",{"type":28,"investigatorFullName":20,"investigatorTitle":20,"investigatorAffiliation":20,"oldNameTitle":20,"oldOrganization":20},"SPONSOR","100619381","quantification-of-systemic-congestion-by-ultrasound-as-a-predictor-of-weaning-failure-from-mechanical-ventilation-100619381",false,"NCT07343882","Quantification of Systemic Congestion by Ultrasound As a Predictor of Weaning Failure From Mechanical Ventilation","SCOUT","Inclusion Criteria:\n\n* Patients aged \\> 18 years.\n* Admitted to an Intensive Care Unit (ICU).\n* Requiring invasive mechanical ventilation for more than 48 hours.\n* Meeting the center's standard criteria to begin weaning and undergo an SBT.\n\nExclusion Criteria:\n\n* Inadequate ultrasound window for assessment.\n* Presence of \"do not reintubate\" orders.\n* Patients with a tracheostomy.\n* Presence of atrial fibrillation.\n* Diagnosed liver cirrhosis (portal hypertension).\n* Absence of qualified personnel to perform the ultrasound at the time of the SBT.\n* Denial of informed consent.","ALL","18 Years",{"count":39,"type":40},350,"ESTIMATED","INTERVENTIONAL",[43],"NA","Mechanical ventilation is an essential, life-saving therapy in the ICU, allowing critically ill patients to rest and recover. Transitioning patients back to spontaneous breathing-known as weaning-is clinically challenging. The first attempt, the Spontaneous Breathing Trial (SBT), fails in 10-30% of cases. Identifying the mechanisms behind failure is crucial, as unsuccessful weaning prolongs ICU stay and increases the risk of reintubation, which worsens prognosis. The SCOUT study aims to improve prediction and management of weaning failure.\n\nThe main objective of the study is to evaluate whether a specific ultrasound-based method, the Venous Excess Ultrasound Score (VExUS), can predict failure of weaning from mechanical ventilation. A key pathophysiological factor is systemic venous congestion. When a patient initiates an SBT, the increased respiratory effort shifts venous return and may precipitate cardiovascular decompensation with pulmonary fluid accumulation, termed weaning-induced pulmonary edema (WIPO). Notably, this may occur even in patients without known cardiac disease.\n\nDetecting clinically relevant congestion before SBT is difficult. Fluid balance and body weight are imprecise, physical examination lacks sensitivity, and biomarkers such as NT-proBNP have limited predictive capacity. VExUS offers a promising, non-invasive approach by directly assessing venous flow patterns in major veins (inferior vena cava, hepatic, portal, and renal veins), providing an estimation of systemic venous pressure and congestion. The central hypothesis is that elevated VExUS grades prior to SBT will identify patients at high risk of failure, enabling proactive optimization and potentially improving outcomes.\n\nSCOUT is designed as a prospective, multicenter, observational study. Standard clinical management of mechanical ventilation and weaning remains unchanged. After informed consent, baseline data will be obtained immediately before SBT, including vital signs, ventilator parameters, blood sampling, and three non-invasive ultrasound assessments: cardiac, pulmonary, and VExUS. During the 30-120-minute SBT, the patient breathes with reduced ventilatory support while their clinical tolerance is evaluated. At the end of the SBT, selected measurements are repeated. Weaning failure is defined as: early termination of SBT due to intolerance, need for invasive or non-invasive ventilation within 48 h after extubation, or death within 48 h. Data are anonymized and stored securely (REDCap) in compliance with Spanish and EU data protection regulations.\n\nThe study is low-risk and provides no direct individual benefit, but may benefit future ICU patients by improving weaning strategies and prognostication.",[46,47,48,49,50],"Weaning Failure","Pulmonary Edema - Acute","Mechanical Ventilation","POCUS","VExUS",[52,53],"Weaning induced pulmonary edema","Venous Excess Ultrasound grading system","NOT_YET_RECRUITING","2026-01-16",{"date":57,"type":58},"2026-01-21","ACTUAL",{"date":60,"type":40},"2026-04-01",{"date":62,"type":40},"2027-06-01",{"name":5,"class":6}]