[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-study-detail:100236070":3},{"organization":4,"armGroups":7,"interventions":13,"overallOfficials":19,"centralContacts":24,"locations":34,"responsibleParty":52,"collaborators":18,"id":56,"slug":57,"hasResults":58,"nctId":59,"briefTitle":60,"officialTitle":60,"acronym":18,"eligibilityCriteria":61,"healthyVolunteers":58,"sex":62,"minAge":63,"maxAge":64,"enrollmentInfo":65,"targetDuration":18,"studyType":68,"phases":69,"briefSummary":71,"conditions":72,"keywords":74,"overallStatus":37,"whyStopped":18,"lastUpdateSubmitDate":78,"lastUpdatePostDateStruct":79,"startDateStruct":82,"completionDateStruct":84,"leadSponsor":86,"locationsCount":87},{"fullName":5,"class":6},"Western University, Canada","OTHER",[8],{"label":9,"type":6,"description":10,"interventionNames":11},"Asthma Patients","All enrolled asthma patients will undergo hyperpolarized noble gas MRI with Helium-3 and\u002For Xenon-129, Pulmonary Function Tests, Quality of Life Questionnaires, dyspnea scales in two visits over three years.",[12],"Other: Hyperpolarized Noble Gas MRI",[14],{"type":6,"name":15,"description":16,"armGroupLabels":17,"otherNames":18},"Hyperpolarized Noble Gas MRI","Hyperpolarized Helium-3 and\u002For Xenon-129. Noble gas magnetic resonance imaging (MRI) has recently emerged as another research approach for the non-invasive measurement of lung structure and function, including conduction of gas through airways and into airspaces.\n\nNoble gas MRI provides a complimentary and alternative method for evaluating lung disease and may be superior to CT because it allows simultaneous visualization of both airway and airspace structure and function.",[9],null,[20],{"name":21,"affiliation":22,"role":23},"Grace E Parraga, PhD","Robarts Research Institute, The University of Western Ontario","PRINCIPAL_INVESTIGATOR",[25,29],{"name":21,"role":26,"phone":27,"phoneExt":18,"email":28},"CONTACT","519-931-5265","gparraga@robarts.ca",{"name":30,"role":26,"phone":31,"phoneExt":32,"email":33},"Angela P Wilson, RRT","519-931-5777","24197","awilson@robarts.ca",[35],{"facility":36,"status":37,"city":38,"state":39,"zip":40,"country":41,"countryCode":42,"cosmosGeoPoint":43,"geoPoint":48,"contacts":49},"Robarts Research Institute; The University of Western Ontario; London Health Sciences Centre","RECRUITING","London","Ontario","N6A 5B7","Canada","CA",{"type":44,"coordinates":45},"Point",[46,47],-81.23304,42.98339,{"lat":47,"lon":46},[50,51],{"name":21,"role":26,"phone":27,"phoneExt":18,"email":28},{"name":30,"role":26,"phone":31,"phoneExt":32,"email":33},{"type":53,"investigatorFullName":54,"investigatorTitle":55,"investigatorAffiliation":5,"oldNameTitle":18,"oldOrganization":18},"SPONSOR_INVESTIGATOR","Dr. Grace Parraga","PhD, Scientist. Robarts Research Institute","100236070","structure-and-function-mri-of-asthma-100236070",false,"NCT02351141","Structure and Function MRI of Asthma","Inclusion Criteria:\n\n* Subjects male and female aged 18-60 with a clinical diagnosis of asthma\n* Smoking history ≤ 1 pack\u002Fyear\n* Subject understands the study procedures and is willing to participate in the study as indicated by signature on the informed consent\n* Subject is judged to be in otherwise stable health on the basis of medical history\n* Subject able to perform reproducible pulmonary function testing (i.e., the 3 best acceptable spirograms have FEV1 values that do not vary more than 5% of the largest value or more than 100 ml, whichever is greater.)\n* FEV1 \\>60% predicted\n\nExclusion Criteria:\n\n* Patient is, in the opinion of the investigator, mentally or legally incapacitated, preventing informed consent from being obtained, or cannot read or understand the written material\n* Patient is unable to perform spirometry or plethysmography maneuvers\n* Subject has an implanted mechanically, electrically or magnetically activated device or any metal in their body which cannot be removed, including but not limited to pacemakers, neurostimulators, biostimulators, implanted insulin pumps, aneurysm clips, bioprosthesis, artificial limb, metallic fragment or foreign body, shunt, surgical staples (including clips or metallic sutures and\u002For ear implants.) (At the discretion of the MRI Technologist\u002F3T Manager)\n* In the investigator's opinion, subject suffers from any physical, psychological or other condition(s) that might prevent performance of the MRI, such as severe claustrophobia.\n* Patient is pregnant","ALL","18 Years","60 Years",{"count":66,"type":67},200,"ESTIMATED","INTERVENTIONAL",[70],"NA","The investigators will apply 129Xenon and\u002For 3He image acquisition and analysis methods in 200 asthma patient volunteers in order to characterize and probe the relationship between lung structure and function using imaging.",[73],"Asthma",[75,76,77],"Noble Gas MRI","Pulmonary Function","Quality of Life Questionnaires","2025-08-08",{"date":80,"type":81},"2025-08-11","ACTUAL",{"date":83,"type":81},"2015-01",{"date":85,"type":67},"2028-12",{"name":54,"class":6},1]