[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"health-studies-list:{\"conditionNormalized\":\"rheumatoid-arthritis-of-hip\",\"overallStatus\":[\"RECRUITING\",\"AVAILABLE\",\"NOT_YET_RECRUITING\"],\"orderBy\":\"LastUpdateSubmitDate:desc\",\"size\":25,\"offset\":0}":3,"health-study-condition:rheumatoid-arthritis-of-hip":30},{"pageToken":4,"total":5,"offset":6,"count":5,"results":7},null,1,0,[8],{"id":9,"slug":10,"hasResults":11,"nctId":12,"briefTitle":13,"officialTitle":14,"acronym":4,"eligibilityCriteria":15,"healthyVolunteers":16,"sex":17,"minAge":18,"maxAge":4,"enrollmentInfo":19,"targetDuration":4,"studyType":22,"phases":23,"briefSummary":25,"conditions":26,"keywords":4,"overallStatus":35,"whyStopped":4,"lastUpdateSubmitDate":36,"lastUpdatePostDateStruct":37,"startDateStruct":40,"completionDateStruct":42,"leadSponsor":44,"locationsCount":47},"100420387","g7-acetabular-system-with-vivacit-e-or-longevity-liner-pmcf-study-100420387",false,"NCT04754087","G7 Acetabular System With Vivacit-E or Longevity Liner PMCF Study","Global, Multicenter, and Prospective Post-Market Clinical Follow-Up Study of the G7 Acetabular System With Vivacit-E and Longevity Highly Crosslinked Polyethylene (HXLPE) Liners & Instrumentation","Inclusion Criteria:\n\n* Patient must be a legal adult who has reached full skeletal maturity.\n* Patient must be treated for one of the following indications:\n* Noninflammatory degenerative joint disease including osteoarthritis and avascular necrosis\n* Rheumatoid arthritis\n* Correction of functional deformity\n* Treatment of non-union, femoral neck fracture, and trochanteric fractures of the proximal femur with head involvement, unmanageable by other techniques\n* Revision procedures where other treatment or devices have failed\n* Patient must be able and willing to complete the protocol required follow-up visits.\n* Patient must be able and willing to sign the Institutional Review Board or Ethics Committee (IRB\u002FEC) approved informed consent.\n\nExclusion Criteria:\n\n* Patient presents with osteoporosis, which in the opinion of the Principal Investigator, may limit the subject's ability to support total hip arthroplasty using the study device.\n* Patient has a metabolic disorder that may impair bone formation.\n* Patient has osteomalacia.\n* Patient has distant foci of infections which may spread to the implant site or patient with infection, sepsis or osteomyelitis.\n* Patient has rapid joint destruction, marked bone loss or bone resorption apparent on roentgenogram.\n* Patient has a vascular insufficiency, muscular atrophy, or neuromuscular disease\n* Patient is a prisoner.\n* Patient is a current alcohol or drug abuser.\n* Uncooperative patient or patient with neurologic disorders who is incapable or unwilling to follow directions.\n* Patient is pregnant.",true,"ALL","18 Years",{"count":20,"type":21},300,"ESTIMATED","INTERVENTIONAL",[24],"NA","The main objectives of this study are to confirm the long-term safety, performance, and clinical benefits of the G7 Acetabular Shells when used with the Vivacit-E and Longevity HXLPE liners and instrumentation in primary and revision total hip arthroplasty.",[27,28,29,30,31,32,33,34],"Total Hip Arthroplasty","Degenerative Joint Disease of Hip","Avascular Necrosis of Hip","Rheumatoid Arthritis of Hip","Osteoarthritis, Hip","Osteoarthritis of Hip","Fractures, Hip","Fracture of Hip","RECRUITING","2025-06-13",{"date":38,"type":39},"2025-06-18","ACTUAL",{"date":41,"type":39},"2021-07-07",{"date":43,"type":21},"2033-12-31",{"name":45,"class":46},"Zimmer Biomet","INDUSTRY",11]