About this trial
Retention of airway secretions is a frequent complication in critically ill patients requiring invasive mechanical ventilation (MV).This complication is often due to excessive secretion production and ineffective secretion clearance.
Mechanical insufflator-exsufflator (MI-E) is a respiratory physiotherapy technique that aims to assist or simulate a normal cough by using an electro-mechanical dedicated device. A positive airway pressure is delivered to the airways, in order to hyperinflate the lungs, followed by a rapid change to negative pressure that promotes a rapid exhalation and enhances peak expiratory flows.
However, there is no consensus on the best MI-E settings to facilitate secretion clearance in these patients. Inspiratory and expiratory pressures of ±40 cmH2O and inspiratory-expiratory time of 3 and 2 seconds, respectively, are often used as a standard for MI-E programming in the daily routine practice, but recent laboratory studies have shown significant benefits when MI-E setting is optimized to promote an expiratory flow bias.
The investigators designed this study to compare the effects of MI-E with an optimized setting versus a standard setting on the wet volume of suctioned sputum in intubated critically ill patients on invasive MV for more than 48 hours.
Eligibility criteria
Qualifiers
Adults (> 18yo).
Endotracheal intubation and invasive mechanical ventilation for > 48h and active humidification for > 24h.
Richmond Agitation-Sedation Scale -3 to -5.
Signed informed consent.
Disqualifiers
Patients with hemodynamic instability (MAP < 60 or > 110, Heart Rate < 50 or > 130, new onset arrhythmias), respiratory instability (PEEP > 12cmH2O, SpO2 < 90% or fraction of inspired oxygen (FiO2) > 60%).
Undrained pneumothorax/pneumomediastinum.
Unstable intracranial pressure (ICP > 20mmHg or MAP < 60).
Severe bronchospasm.
Trial design
Treatments tested in this trial
- MI-E Intervention protocol
- Standard MI-E setting