Optimal Pacing Rate for Cardiac Resynchronization Therapy

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-90
SponsorMedstar Health Research Institute

About this trial

This is a prospective, randomized crossover study. The objective of the study is to determine if a pacing rate of 80 beats per minute (bpm) improves exercise tolerance during the 6-minute walk test. The investigators will randomly assign half of the participants to a starting rate of 60 bpm and then switch them to a rate of 80 bpm for 3 months, and vice versa.

Eligibility criteria

Qualifiers

Age 18 years or older

History of persistent or permanent atrial fibrillation

Implantation of CRT or conduction system pacing in prior 3 months to 5 years of study start

History of intrinsic AVN block or have undergone AVN ablation in prior 3 months to 5 years of study start

Disqualifiers

LVEF <50%

Wide QRS (greater than 150ms)

Isolated RV pacing

Severe valvular disease

Trial design

Treatments tested in this trial

  • Pacing rate of 80 bpm
  • Pacing rate of 60 bpm

Treatment groups

60 Participants
are divided into 2 treatment groups

Sponsors and collaborators