The Utility of Hand-held Ultrasound Devices to Detect Bowel Wall Inflammatory Activity in Crohn's Disease

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorSheba Medical Center

About this trial

One of the major obstacles in implementing intestinal ultrasound services for inflammatory bowel disease (IBD) patients relates to the costs of acquiring ultrasound (US) machines. The costs of high-end (and higher levels of quality) US machines are considerable, and although large medical centers in developed countries can obtain US machines, smaller centers in rural areas, community centers and centers in undeveloped countries may struggle with the cost of the machines. The lack of availability of point-of-care intestinal ultrasound impedes the medical treatment IBD patients receive. Recently, new models of hand-held small ultrasound machines were introduced to the market by large ultrasound companies. These machines are affordable and are used mainly for point-of-care ultrasound exams. We hypothesize that if the image quality acquired by these machines is proven to be good enough for the detection of bowel inflammation and complications in Crohn's disease (CD) patients, the use of intestinal ultrasound can potentially increase, allowing better care for CD patients.

Our idea is to compare the accuracy of various hand-held ultrasound devices to detect ultrasonographic signs of bowel inflammatory activity (especially increased bowel wall thickness) to that of high-end and premium US machines. The first part of the project will include examining the quality of 2 different hand-held US machines (GE VSCAN air and Philips Lumify) by 3 experienced ultra-sonographers. If the achieved level of accuracy for the detection of bowel wall inflammatory activity will be sufficient (AUC\>0.8), we aim to move to the second part of the project. This step focuses on hand-held US machines by gastroenterologists with various levels of IUS experience. Therefore, we aim to examine the accuracy of hand-held US machines for the detection of inflammatory activity by delivering the hand-held US machines to 10 GI specialists who completed the IBUS educational curriculum for IUS (at least module 1+2) with various levels of IUS expertise.

* Project Goal 1) To examine the capability and accuracy of hand-held ultrasound machines to detect bowel wall inflammatory activity and complications in CD patients. * Strategy - Comparing various ultrasonographic signs of inflammation acquired by hand-held US machines to that acquired by high-end and premium US machines. * Outcomes - Accuracy of hand-held ultrasound machines in the detection of bowel wall inflammatory activity The problem being addressed by the proposed project - Dissemination of IUS is limited due to the high costs of US machines. The use of affordable hand-held US machines for the detection of inflammatory activity will expand the IUS incorporation into the CD diagnosis, monitoring, and treatment approaches, improving patient outcomes.

Significance/Impact The use of affordable and precise US machines will disseminate the use of IUS and expand the IUS incorporation into the diagnosis, monitoring, and treatment of CD, improving patient outcomes

Eligibility criteria

Qualifiers

None

Disqualifiers

Pregnancy Inability to visualize he bowel on US Proximal Crohn's disease Proctitis

Trial design

Treatments tested in this trial

  • Intestinal ultrasound

Treatment groups

150 Participants
are divided into 1 treatment group

Locations

This trial has no locations

Sponsors and collaborators

Sheba Medical Center

Lead sponsor

The Leona M. and Harry B. Helmsley Charitable Trust

Collaborator