Ischemic Stroke, Cryptogenic

2

Review clinical trials related to Ischemic Stroke, Cryptogenic. Use filters to narrow results by trial status, phase, treatment, biological sex and sponsor.

Condition / disease
Location
Status: Recruiting

Left Atrial Strain and Cryptogenic Stroke

Cryptogenic stroke is a type of stroke in which the cause of the blood clot cannot be identified, leaving many patients without a clear treatment plan and at high risk for another stroke. Current medical guidelines recommend blood-thinning medication (anticoagulation) only when atrial fibrillation (AF) -an irregular heart rhythm- can be documented. However, AF may occur silently and remain undetected. Long term implantable (placed invasively under the skin) devices may be needed to capture these episodes. AF is known to develop from disease of the left atrium, the upper chamber of the heart that receives blood from the lungs. When the left atrium does not contract normally, blood flow may slow down, increasing the risk of clot formation. Nowadays, the left atrial (LA) function can be quantified precisely using a noninvasive ultrasound technique called strain imaging. This study aims to determine whether reduced LA function is associated with cryptogenic stroke and its recurrence even when AF is not observed. If such an association is confirmed, LA strain could serve as a new biomarker to identify patients at risk, earlier than the development of overt AF, enhance preventive measures to reduce recurrent strokes. Because echocardiographic strain imaging is safe, cost-effective, and widely available, it may become an important tool for improving care in this high-risk population.

Participants needed: 900
Trial details
Age: 18+Biological sex: AllType: ObservationalSponsor: University of PittsburghUpdated: Jan 7, 2026Locations: 1
Eligibility criteria

Adult patients (age > 18 years and < 80 years) who had a complete transthoracic...

Status: Recruiting

Smartwatches for Detection of Atrial Fibrillation (AFib) in Secondary Prevention of Cryptogenic Stroke

Scientific Background: In secondary prevention of ischemic stroke, detection of atrial fibrillation (AFib) and subsequent anticoagulation therapy reduce the risk of recurrent stroke by approximately 60%. Prolonged electrocardiogram (ECG) monitoring up to 6 months significantly increases detection of AFib in cryptogenic stroke. Wearables like smartwatches have recently been shown to adequately detect AFib in the general population. Thus, prolonged ECG monitoring after cryptogenic ischemic stroke or transient ischemic attack (TIA) using a smartwatch could lead to a reduction of recurrent stroke by prompting adequate anticoagulation therapy and may constitute a cost-effective, non-invasive, and broadly-available alternative to the current standard of care. Hypothesis: The investigators hypothesize that AFib detection via smartwatch in patients with cryptogenic TIA or ischemic stroke is accurate compared to an implantable event recorder. Methods: The investigators introduce a prospective, intraindividual-controlled, multicentre clinical study in patients with cryptogenic ischemic stroke or TIA. In addition to an implanted event recorder as indicated by clinical standard, included patients receive a smartwatch for detection of AFib. ECG-data from smartwatches will be continuously monitored by two independent cardiologists. As soon as AFib is confirmed, a doctoral appointment is set to evaluate start of anticoagulation. The follow-up period will be six months. The study consists of four study visits: a baseline visit, two phone visits at one and three months, and an end of trial visit at six months. Primary Objective: To compare smartwatch and event recorder based analysis for sensitivity and specificity of AFib detection per patient after six months

Participants needed: 400
Trial details
Age: 40+Biological sex: AllType: InterventionalSponsor: Technical University of MunichUpdated: Dec 13, 2024Locations: 1
Eligibility criteria

Implanted Event Recorder with telemedicinal function (e.g., Biotronik BioMon 3m... [+13]

Patient is not able to perform 1-lead ECG recording with smartwatch [+3]