Clinical trials

2

Search and review clinical trials. Use filters to narrow results by trial status, phase, treatment, biological sex and sponsor.

Condition / disease
Location
Status: Not yet recruiting

Clinical and Radiographic Outcomes of the JointMedica Custom-Made Resurfacing Device

The Custom Resurfacing (CR) Implants are indicated for use for the reduction or relief of pain and/or improved hip function all skeletally mature patients where a total joint replacement is indicated, and where there is no other suitable, commercially distributed device available. The Resurfacing System is a metal-on-polyethylene hip resurfacing device consisting of a metallic femoral component and an acetabular component made of Vitamin E HXLPE with a titanium coating on its bone-contacting surface. The custom-Made Hip Resurfacing System is a single use device intended for hybrid fixation: cemented femoral head component and cementless acetabular component. The goal of this observational study is to generate Real World Evidence (RWE) on the device performance of the Polymotion Hip Resurfacing (PHR) system and its use in patients who have been implanted with the device for the treatment of hip osteoarthritis. This study will assess the following endpoints: * The survivorship of the Acetabular Cup (Kaplan-Meier estimate) through 2 years of follow-up. * Radiographic success of the implanted cups, through quantitative motion analysis to assess migration of the acetabular cups. * Absence of subsequent surgical intervention at the acetabulum of there operated hip. * Absence of serious, device-related adverse events. * Patient reported outcomes through Harris Hip Score and SUSHI - UCLA Hip Score questionnaires.

Participants needed: 41
Trial details
Age: 21+Biological sex: AllType: ObservationalSponsor: JointMedica Inc.Updated: Jul 30, 2025Locations: 1
Eligibility criteria

Age 21 or above at the time of the surgery. [+2]

There is no exclusion criteria for this study

Status: Not yet recruiting

Clinical and Radiographic Outcomes of the JointMedica Polymotion Resurfacing (PHR) Device

The goal of this observational study is to generate Real World Evidence (RWE) on the device performance of the Polymotion Hip Resurfacing (PHR) system and its use in patients who have been implanted with the device for the treatment of hip osteoarthritis. This study will assess the following endpoints: * The survivorship of the Acetabular Cup (Kaplan-Meier estimate) through 2 years of follow-up. * Radiographic success of the implanted cups, through quantitative motion analysis to assess migration of the acetabular cups. * Absence of subsequent surgical intervention at the acetabulum of there operated hip. * Absence of serious, device-related adverse events. * Patient reported outcomes through Harris Hip Score and SUSHI - UCLA Hip Score questionnaires.

Participants needed: 105
Trial details
Age: 21+Biological sex: AllType: ObservationalSponsor: JointMedica Inc.Updated: Jul 23, 2025Locations: 3
Eligibility criteria

Age 21 or above at the time of the surgery. [+2]

There is no exclusion criteria for this study