Clinical trials

2

Search and review clinical trials. Use filters to narrow results by trial status, phase, treatment, biological sex and sponsor.

Condition / disease
Location
Status: Not yet recruiting

Clinical Accuracy Validation of the Moni-Patc Temperature Monitoring Patch During Surgery (Compared With Esophageal and Bladder Temperature)

Moni-Patc Temperature Monitoring Patch System, a non-invasive, continuous temperature monitoring device designed to estimate core body temperature by applying a Sensor to the neck.This clinical accuracy validation study aims to verify the accuracy and repeatability of the Moni-Patch compared with an FDA-cleared continuous esophageal and bladder temperature monitoring device used as the clinical reference.Main ObjectivesTo verify that the Moni-Patch and the reference device(esophageal and bladder) demonstrate acceptable agreement, as defined by Bland-Altman Analyses (bias within ±0.4°C and limits of agreement between -1.0°C and 1.0°C).To verify the consistency and repeatability of temperature measurements obtained from the Moni-Patch during continuous monitoring.

Participants needed: 30
Trial details
Age: 18+Biological sex: AllType: ObservationalSponsor: Murata Vios, Inc.Updated: Feb 9, 2026
Eligibility criteria

Age ≥18 years [+7]

Subjects unable to provide their own consent. Consent from family or LOR is not... [+7]

Status: Not yet recruiting

Clinical Accuracy Validation of the Moni-Patch Temperature Monitoring Patch System

Moni-Patch Temperature Monitoring Patch System, a non-invasive, continuous temperature monitoring device designed to estimate core body temperature by applying a Sensor to the neck. This clinical accuracy validation study aims to verify the accuracy and repeatability of the Moni-Patch compared with an FDA-cleared continuous tympanic temperature monitoring device used as the clinical reference. Main objectives of this study are; To verify that the Moni-Patch and the reference device(tympanic) demonstrate acceptable agreement, as defined by Bland-Altman Analyses (bias within ±0.4°C and limits of agreement between -1.0°C and 1.0°C). To verify the consistency and repeatability of temperature measurements obtained from the Moni-Patch during continuous monitoring.

Participants needed: 105
Trial details
Age: 7+Biological sex: AllType: InterventionalSponsor: Murata Vios, Inc.Updated: Feb 9, 2026Locations: 1
Eligibility criteria

Age ≥ 7 years [+1]

Ear conditions contraindicating tympanic probe; skin issues at placement sites [+2]